메뉴 건너뛰기
페이지 확대

Gas Insulated Switchgear To meet various requirements for substations, Hyosung designs and manufactures a wide range of SF6 GIS system. ItisHyosungsstrengthtosupplyhigh-qualityproductsatacompetitiveprice.Hyosung GIS is used in various sites including building, factory, subway and other public facilities requiring high reliability, stability and minimum floor area. Hyosung can design and manufacture the product that fulfills the requirements of the clients 100% in anywhere in the world. Hyosung designs and manufactures various types of SF6 GISofmaximumratedbreakingcurrentof63kAandtheratedvoltagerangingfrom24kVto800kV. AllthemodelscomplywithIEC,ANSI,IEEEandotherinternationalstandardsandareexported to the clients around the world. KERI Certification KERI Certification KERI Certification ISO9001 ISO14001 Hyosung GIS Series Hyosung MV GIS Spec. Model Economy General Heavy duty Export External shape Shape 550 × 1200 × 2350 700 × 2100 × 2700 600 × 1800 × 2350 SIZE (W×D×H) 650 × 1200 × 2050 600 × 2100 × 2600 600 × 1200 × 2350 800 × 2200 × 2700 700 × 2200 × 2700 Rated voltage 24kV 25.8kV 25.8kV 25.8 / 36kV 36(38)kV Rating Rated current 1250 / 2000A 630 / 1250 / 2000A 600 / 2000A 1250 / 2500 / 3150 / 4000A 1250 / 2500A Instantaneous 25kA / 3sec 25kA / 3sec 25kA / 1sec 40kA / 3sec 31.5(40)kA / 3sec Current I 04 05 ProGIS

Main Features Hyosung GIS is designed for maximum safety of product and user Compartmentalized structure Gas compartment structure prevents expansion of accident to the whole area. Bellows at the tank connector Bellows absorbs temperature changes, tolerances in assembly, differential settlement of concrete base, and excessive displacement caused due to earthquake, maintaining mechanical safety of the system. GIS model that passes the internal arc test Hyosung GIS is C-GIS that passed the internal arc test and is recognized with its stability in operation. Satisfy customer’s needs by the world’s first commercially available of 4000A, 3150A main bus Offer bets solution considering the customer installed capacity. Hyosung GIS adopts the best design technology available Hyosung GIS adopts the latest design technologies such as 3-D electromagnetic analysis, structural analysis and heat distribution analysis, based on the know-how acquired through development of ultra high voltage GIS such as 362kV and 800kV. Insulation performance test (Electric field analysis) Magnetic Field Analysis Techniques VCB Design test_Electric field analysis DS Design test_ Electric field analysis current density vector customer temperature rise percentage of allowance customer temperature rise percentage of allowance limitation limitation permission permission electric field 1.0 p.u ㎸/㎜ less percentage of allowance electric field 1.0 p.u ㎸/㎜ less percentage of allowance strength strength electric field magnetic flux density Design criterion 8% strength to 0.92 p.u ㎸/㎜ maximum electric 0.901 p.u ㎸/㎜ Design criterion 10% ground percentage of allowance field strength percentage of allowance interpolar electric Design criterion 5% field strength 0.85 p.u ㎸/㎜ percentage of allowance - rated gas pressure : 0.1 Mpa - rated gas pressure : 0.1 Mpa current-applying performance verification (analysis of heat flow) 3-D design calculation temperature desired analysis percentage of customer rise limitation value value allowance VCB operating 75k 65k 63.1k 16% connection VCB fixed 75k 65k 53.4k 29% connection temperature desired percentage of position rise limitation value test value allowance VCB operating 75k 65k 61.2k 18% connection VCB fixed 75k 65k 49.6k 34% connection Secure 4000A electric current-applying performance and target percentage of allowance above 15% by meets the temperature rise threshold by design improvements of VCB Heat dissipation structure.

탐 색

메 일